FTYS-3000 Testing Equipment X-ray Fluorescence Sulfur Analyzer ASTM D4294 Sulfur Tester
Product Description
The FTYS-3000 X-ray Fluorescence Sulfur Analyzer produced by our company is a special X-ray fluorescence analyzer developed and manufactured to meet the needs of sulfur content detection in oil products. It adopts the energy dispersion principle, electrical-mechanical-microprocessor integration design, fast analysis speed, and its repeatability and reproducibility meet the testing standards ASTM D4294, GB/T 17040 and GB 11140. It provides an important means for the detection of sulfur content in crude oil or petrochemical production. This analyzer is environmentally friendly and cost effective.
Main Features :
1. With electrical-mechanical-microprocessor integration design, compact and beautiful;
2. With an 8-inch wide-viewing angle capacitive touch screen display. The backlight brightness can be set by software, without a keyboard, and the interface is simple.
3. Wide range of detection products, wide detection range, fast analysis speed, and low consumption of standard samples.
4. Adopts the fluorescence intensity ratio analysis method,temperature and air pressure are automatically corrected, and the carbon-hydrogen ratio (C/H) can also be corrected.
5. The automatic diagnosis function of the instrument can judge the working status and electrical parameters of the instrument.
6. The disposable Mylar film sample cup is used to avoid cross contamination; the sample cup is made of multifunctional
pressing parts, which is quick and convenient.
7. The sample holderis accurately positioned, and it is very convenient to place samples and replace oil leakage prevention parts, and avoid the possibility of contamination of the detection system.
8. Has a large data storage capacity, which canstore 4096 analysis results, 8192 counting measurement data by default, and 16 instrument calibration result data. The data can be browsed at any time.
9. Equipped with RS232port, it can connect with any PC.
10. Has automatic peak stabilization function. When the detector performance decreases, the system can automatically adjust the high voltage and correct the error.
11. Automatically select the working curve by default when it ispoweron, without user intervention.
12. 12. The user can select the measurement result unit, ppm or (m/m)%.
13. 13. Safe radiation protection measures, no ionizing radiation harm to individuals and public.
Measurement range |
7 ppm ~ 5% |
Repeatability (r) |
<0.02894 (X+0.1691) |
Reproducibility (r) |
<0.1215 (X+0.05555) |
Oil sample quantity |
3 ml (equal to sample depth of 3 mm~4 mm); |
Measurement time |
30s, 60s, 90s, 120s, 150s, arbitrarily set |
Single sample automatic measurement, measurement times |
1, 2, 3, 5, 10 times arbitrarily set, the average value and standard deviation are given after measurement |
Calibration curve numbers |
Can store 10 calibration curves |
Working condition |
Ambient temperature: 5~40ºC; Relative humidity: <=85% (30 ºC); |
Power supply |
220V±20V, 50 Hz; |
Rated power |
50W |
Dimensions |
460mm×260mm ×260mm |
Weight |
13 kg |