• ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
  • ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
  • ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
  • ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
  • ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
  • ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

After-sales Service: Online, Video, Call, Email Supports or on-Site
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester pictures & photos
ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
US $4,300-5,500 / Set
Min. Order: 1 Set
Manufacturer/Factory, Trading Company
Gold Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Chongqing, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (21)
  • Overview
  • Detailed Photos
  • Features
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
Tan Delta Oil Tester
Mass Scope of Workpiece
21 Kgs
Type
Insulating Oil Dielectric Loss Tester
Accuracy Grade
+-0.5%
Display
Digital
Control
Computer Control
Weight
21 Kgs
Power Source
AC 220V, 50Hz
Measurement Range 01
Capacitance: 5PF-200PF
Measurement Range 02
Relative Permitity 1.000 ~ 30.000
Measurement Range 03
Dielectric Loss Factor: 0.00001 ~ 100
Measurement Range 04
DC Resistivity: 2.5 MΩm-20 TΩm
Temperature Range
0 ~ 125 Degree
Temperature Measurement Error
+-0.5 Degree
AC Experimental Voltage
0 ~ 2200V, Adjustable Continuously
DC Test Voltage
0 ~ 600V, Adjustable Continuously
Power Consumption
100W
Ambient Temperature
0 ~ 40 Degree
Relative Humidity
Less Than 80%
Certificate
CE, ISO, SGS
Delivery Time
7 Days
Transport Package
in Standard Exportation Plywood Case
Specification
420 * 380 *385mm3
Trademark
FUOOTECH
Origin
Chongqing, China
HS Code
9030899090
Production Capacity
2000 PCS/Month

Packaging & Delivery

Package Size
50.00cm * 36.00cm * 42.00cm
Package Gross Weight
22.000kg

Product Description

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

FT-YJS-059 Automatic Insulating Oil Dielectric loss and resistivity tester designed  according to ASTM D924 and GB/5654 standards, which it is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument integrates with test oil cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components.

Transformer oil dielectric loss testing equipment is used both at the stage of checking the quality of oil before feeding it into the transformer and during the use of oil in the transformer.

The primary enemies of transformer oil are oxidation, contamination, and excessive temperature. High values of Tan Delta commensurate with reduced levels of Resistivity indicate the presence of polarised contaminants, such as moisture, particles and fibres. This testing is a sensitive way to check for contamination when purchasing unused new oil, determining the progress of the oil purification process and for quality control of oil in service.




ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

Detailed Photos

 

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

 

Features
1). The test cell adopts the three-electrode structure according to national standard GB/T5654-2007, with electrode spacing 2mm, which can eliminate the effects of the stray capacitance and leakage on dielectric loss test results.

2). The instrument adopts the medium frequency induction heating, PID temperature control algorithm. This heating method has the advantages of non-contact between the test cell and the heating body, uniform heating, fast speed, convenient control, and strictly control of the temperature within error range of the preset temperature.

3). Internal standard capacitor is SF6 gas-filled three-electrode capacitance, and its capacitor dielectric loss and electrical capacity are not affected by ambient temperature, humidity etc., so that the instrument accuracy can be ensured even after prolonged use.

4). AC test power supply uses AC-DC-AC conversion, which effectively prevents the fluctuations in mains voltage and frequency from affecting the dielectric loss measurement accuracy. Even use a generator, the instrument can work properly.

5). Perfect protection function. When there is over voltage, over current or high-voltage short circuit, instruments can quickly cut off high voltage, and issues a warning message. When the temperature of the sensor failure or not connected, the instrument will also issue a warning message.

6). There is a temperature limiting relay in the medium frequency induction heating furnace. When temperature above 120 degrees, the instrument frees the relay and stops heating.

7). Convenient test parameter setting. Temperature setting range 0~120ºC, AC voltage setting range 500~2200V, DC voltage setting range 300~500V.

8). Using of large TFT touch screen, with backlight and clear display. With simply set up, the instrument can be automatically tested. And automatically store and print test results.

9). Built-in real-time clock, the test date and time can be saved, displayed and printed with the test results.

10). Calibration functions of cleaned dry cell. The measurement of dry cell's capacitance and dielectric loss factor can determine its cleaning and assembly conditions. The calibration data is automatically saved and so that it facilitates the calculation of relative permittivity and DC resistivity.

 
  • ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor TesterASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
Product Parameters
Voltage supply   AC 220V±10%
Power frequency   50Hz/60Hz ±1%
Measuring range
Capacitance  5pF~200pF
Relative Permittivity  1.000~30.000
Dielectric loss factor   0.00001~100
DC Resistivity   2.5MΩm~20TΩm
Measuring accuracy
Capacitance  ± (1% of reading+0.5pF)
Relative Permittivity   ±(1~10)% of reading
Dielectric dissipation factor  ± (1% of reading+0.0001)
DC Resistivity   ±10% of reading
Resolution 
Capacitance   0.01pF
Relative permittivity  0.001
Dielectric dissipation factor   0.00001
Measured temperature range   0~120ºC
Temperature measurement error   ±0.5ºC
AC Test Voltage   500~2200V Continuously adjustable, frequency: 50Hz
DC Test Voltage  0~500V Continuously adjustable
Power consumption  100W
Ambient temperature 0ºC~40ºC
Relative humidity(RH) <75%
Dimensions   500mm × 360mm × 420mm
Total weight   22KG
 
Certifications

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

 

Packaging & Shipping

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

 

 

 

Company Profile

 

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor TesterASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

 

 

ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester

 

FAQ

1). What's the payment method?
A: Payment can be done by cash T/T, L/C, Western Union, Alibaba Trade Assurance, etc.

2). How long is the delivery period?
A: Generally, it takes about 10 working days for production and then the delivery will be done timely.

3). What's the package made of?
A: The package is made of international export standard wooden case.

4). What's the delivery method?
A: By train, by air, by sea, by truck, by express, etc.

Welcome to visit our website and visit our company, welcome your inquiry and contact.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester pictures & photos
ASTM D924 Transformer Oil Dielectric Loss Tester/ Tan Delta Oil Tester/ Insulating Oil Power Factor Tester
US $4,300-5,500 / Set
Min. Order: 1 Set
Gold Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, ISO 14001
Import & Export Mode
Have Own Export License